Apr 01, 2019 E5CC-800, E5CC-U-800 Digital Temperature Controller (Simple Type) (48 × 48 mm). C Digital Controllers User's Manual (Cat. H174) for information on the operation of the standby.6 The E5CC-U-800 plug-in model is certified for UL listing only when used together with the OMRON P2CF-11 or P2CF-11-E socket. Apr 01, 2019 Digital Temperature Controller (48 x 48 mm) 48 x 48 mm. Large White PV Display That's Easier to Read. Easy to Use, from Model Selection to Setup and Operation. A Complete Range of I/O Capacities, Functions, and Performance. Handles More Applications. E5CC-B is our Value Design product which increase the value of your control panel. Omron E5CC-T Pdf User Manuals. View online or download Omron E5CC-T User Manual.
48 x 48 mm. Large White PV Display That's Easier to Read. Easy to Use, from Model Selection to Setup and Operation. A Complete Range of I/O Capacities, Functions, and Performance. Handles More Applications. E5CC-B is our Value Design product which increase the value of your control panel.
about this Product Family
Related Contents
- Common
- Temperature Controllers
last update: October 2, 2017
Micro hite 600 operation instruction. The 00790034 TESA MICRO-Hite 600 Manual Height Gage does not include the Power Panel (00760163) and must be purchased separately. Below is the list of TESA MICRO-HITE Manual Height Gages: 00790033 TESA MICRO-HITE Manual Height Gage: 0-20'/520mm; 00790034 TESA MICRO-HITE Manual Height Gage: 0-30'/770mm. Digital and Dial Height Gages from Brown and Sharpe, Fowler and Mitutoyo - Tesa Micro-Hite 600 Manual - Tesa Micro-Hite 600 Manual.
Model Number Legend
Models with Screw Terminal Blocks
Heating and Cooling Control
Using Heating and Cooling Control
(1) Control Output Assignment
If there is no control output 2, an auxiliary output is used as the cooling control output.
If there is a control output 2, the two control outputs are used for heating and cooling.
(It does not matter which output is used for heating and which output is used for cooling.)
(2) Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
If there is no control output 2, an auxiliary output is used as the cooling control output.
If there is a control output 2, the two control outputs are used for heating and cooling.
(It does not matter which output is used for heating and which output is used for cooling.)
(2) Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
Omron E5cc Rx2asm 000 Pdf
Models with Push-In Plus Terminal Blocks
Heating and Cooling Control
Using Heating and Cooling Control
(1)Control Output Assignment
An auxiliary output is used as the cooling control output.
(2) Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
An auxiliary output is used as the cooling control output.
(2) Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
Plug-in Models
Control output | No. of auxiliary outputs | Options | Model | Model | ||
---|---|---|---|---|---|---|
HB alarm and HS alarm | No. of event inputs | Communica- tions | Power supply voltage | Power supply voltage | ||
100 to 240 VAC | 24 VAC/DC | |||||
Relay output | --- | --- | --- | --- | E5CC-RW0AUM-000 | E5CC-RW0DUM-000 |
1 | E5CC-RW1AUM-000 | E5CC-RW1DUM-000 | ||||
2 | E5CC-RW2AUM-000 | E5CC-RW2DUM-000 | ||||
Voltage output (for driving SSR) | --- | --- | --- | --- | E5CC-QX0AUM-000 | E5CC-QX0DUM-000 |
1 | E5CC-QX1AUM-000 | E5CC-QX1DUM-000 | ||||
2 | E5CC-QX2AUM-000 | E5CC-QX2DUM-000 | ||||
Linear current output | --- | --- | --- | --- | E5CC-CX0AUM-000 | E5CC-CX0DUM-000 |
1 | E5CC-CX1AUM-000 | E5CC-CX1DUM-000 | ||||
2 | E5CC-CX2AUM-000 | E5CC-CX2DUM-000 |
Heating and Cooling Control
Using Heating and Cooling Control
(1) Control Output Assignment
An auxiliary output is used as the cooling control output.
(2) Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
An auxiliary output is used as the cooling control output.
(2) Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
Optional Products (Order Separately)
USB-Serial Conversion Cable
Terminal Covers (for E5CC)
Canon scanner lide 110 user manual. Note: The E53-COV10 cannot be used.
Refer to Data Sheet for the mounted dimensions. Behringer xenyx x1204 usb user manual.
Refer to Data Sheet for the mounted dimensions. Behringer xenyx x1204 usb user manual.
Waterproof Packing
Note: The Waterproof Packing is provided only with E5CC/E5CC-B Controllers.
The E5CC-U cannot be waterproofed even if the Waterproof Packing is attached.
The E5CC-U cannot be waterproofed even if the Waterproof Packing is attached.
Current Transformers (CTs)
Hole diameter | Model |
---|---|
5.8 mm | E54-CT1 |
5.8 mm | E54-CT1L * |
12.0 mm | E54-CT3 |
12.0 mm | E54-CT3L * |
* Lead wires are included with these CTs. If UL certification is required, use these CTs.
Adapter
Note: Use this Adapter when the panel has already been prepared for an E5B[] Controller.
Waterproof Cover
Mounting Adapter
Note: This Mounting Adapter is provided with the Digital Temperature Controller.
DIN Track Mounting Adapter (for E5CC)
Sockets (for E5CC-U)
Omron E5cc Rx2asm 800 User Manual Software
Type | Model |
---|---|
Front-connecting Socket | P2CF-11 |
Front-connecting Socket with Finger Protection | P2CF-11-E |
Back-connecting Socket | P3GA-11 |
Terminal Cover for Back-connecting socket with Finger Protection | Y92A-48G |
Front Covers
Type | Model |
---|---|
Hard Front Cover | Y92A-48H |
Soft Front Cover | Y92A-48D |
CX-Thermo Support Software
Note: CX-Thermo version 4.5 or higher is required for the E5CC.
CX-Thermo version 4.61 or higher is required for the E5CC-U.
CX-Thermo version 4.65 or higher is required for the E5CC-B.
CX-Thermo version 4.67 or higher is required for the E5CC-B linear current output type.
For the system requirements for the CX-Thermo, refer to information on the EST2-2C-MV4.
CX-Thermo version 4.61 or higher is required for the E5CC-U.
CX-Thermo version 4.65 or higher is required for the E5CC-B.
CX-Thermo version 4.67 or higher is required for the E5CC-B linear current output type.
For the system requirements for the CX-Thermo, refer to information on the EST2-2C-MV4.
last update: October 2, 2017
Product Category
- Control Components
- Temperature Controllers
- General-purpose
- E5CC, E5CC-B, E5CC-U
- General-purpose
- Temperature Controllers
© Copyright OMRON Corporation 2007 - 2019. All Rights Reserved.